Go to www.awrcorp.com
Back to search page Click to download printable version of this guide.

Phase Spec: Grounded Shield, Open (Closed Form): TLOC

Symbol

Summary

TLOC simulates an ideal, lossless open-circuited transmission line. Model implies that line length is specified as electrical length (phase lag of mode propagating along the line) at user specified frequency. User must supply value of characteristic impedance.

Parameters

Name Description Unit Type Default
ID Name Text TL1
Z0 Transmission line impedance Resistance 50 ohm
EL Electrical length (phase length) at F0 Angle 90 Deg
F0 Frequency used to specify EL Frequency 10 GHz

Parameter Details

EL and F0. These parameters determine the frequency dependence of the electrical length of the line, described as βL=EL· freq/Fo · π/180 where freq is the evaluation frequency.

Layout

This element does not have an assigned layout cell. You can assign artwork cells to any element. See “Assigning Artwork Cells to Layout of Schematic Elements” for details.