Go to www.awrcorp.com
Back to search page Click to download printable version of this guide.

Nonlinear Voltage-Controlled Current Source: NLVCCS

Symbol

Parameters

Name Description Unit Type Default
ID Device ID Text VC1
*R1 Input resistance Resistance 1e+06 ohm
*R2 output resistance Resistance 1e+06 ohm
*SC Scale factor   1
*VTH Threshold voltage Voltage -1e+08 V
*TAU Delay Time 0 ns
*A0 Polynomial coefficient   0
*A1 Polynomial coefficient   0.01
*A2 Polynomial coefficient   0
*A3 Polynomial coefficient   0
*A4 Polynomial coefficient   0
*A5 Polynomial coefficient   0
*A6 Polynomial coefficient   0
*A7 Polynomial coefficient   0
*A8 Polynomial coefficient   0
*A9 Polynomial coefficient   0
*A10 Polynomial coefficient   0
*A11 Polynomial coefficient   0
*A12 Polynomial coefficient   0
*A13 Polynomial coefficient   0
*A14 Polynomial coefficient   0
*A15 Polynomial coefficient   0

* indicates a secondary parameter

Implementation Details

For V≤VTH

f(V)=0.0

For V>VTH

where

NOTES:

  1. SC is a scale factor that scales the parameters as if it were a FET.

  2. R1 and R2 are scaled inversely with SC.

  3. TAU is a constant time delay.

  4. The model does not ensure that dI/dV is continuous at VTH. The user should select polynomial coefficients to guarantee this.

Layout

This element does not have an assigned layout cell. You can assign artwork cells to any element. See “Assigning Artwork Cells to Layout of Schematic Elements” for details.