Go to www.awrcorp.com
Back to search page Click to download printable version of this guide.

Analyze Nonlinear Stability Properties: NLSTABILITY

Symbol

Summary

NLSTABILITY instructs the simulator to analyze stability in a nonlinear circuit following large-signal analysis. See “Nonlinear Internal Stability Analysis” for nonlinear stability analysis details.

Parameters

Name Description Unit Type Default
ID Stability control name   ST1
Fstart Small-signal frequency start Frequency 0.1 GHz
Fend Small-signal frequency end Frequency 0.2 GHz
Fsteps Number of points in small-signal frequency sweep   5
SwpType Sweep type   LINEAR

Parameter Details

Fstart and Fend. Define the small-signal frequency range.

SwpType. Allowable sweep types are linear (LINEAR) and logarithmic (LOG).

Layout

This element does not have an assigned layout cell. You can assign artwork cells to any element. See “Assigning Artwork Cells to Layout of Schematic Elements” for details.