Go to www.awrcorp.com
Back to search page Click to download printable version of this guide.

Capacitor with Q (Closed Form): CAPQ

Symbol

Equivalent Circuit

Parameters

Name Description Unit Type Default
ID Name Text C1
C Capacitance Capacitance 1 pF
Q Q at FQ   0
FQ Freq at which Q is determined Frequency 0 GHz
ALPH Scaling exponent for Q   1
DCMod DC modeling Vector text (pull-down) Lossless

Parameter Details

DCMod. Specifies the DC behavior of the model. Lossless indicates that the model is modeled as an ideal capacitor at DC. Lossy indicates that loss is taken into account at DC.

Implementation Details

Implements a capacitor with frequency-dependent Q.

The admittance of the capacitor is given by:

In these equations, f is the simulation frequency.

NOTE: FQ must be greater than or equal to zero.

Layout

This element does not have an assigned layout cell. You can assign artwork cells to any element. See “Assigning Artwork Cells to Layout of Schematic Elements” for details.